| Sign In | Join Free | My ecer.co.uk |
|
Brand Name : Rexroth
Model Number : PV7-1X/40-45RE37MC0-16 PV7-1X/16-30RE01MC5-08 PV7-1X/100-150RE07KD0-08
Certification : ISO
Place of Origin : Germany
MOQ : 1
Payment Terms : Western Union,T/T,D/P,D/A,L/C
Supply Ability : 100
Delivery Time : 2 weeks
Packaging Details : wooden box
Productname : Rexroth Hydraulic Pump
Rotation : 0.2-cp can be transported in reverse
Standard Or Nonstandard : Standard
Pump : piston
Delivery Date : 2. 3, 4, 5 X series
Pumptype : Variable Displacement / Fixed Displacement
Keyword : Rexroth Hydraulic Pump
Material : High-grade Steel and Aluminum
PV7-1X/40-45RE37MC0-16
PV7-1X/16-30RE01MC5-08
PV7-1X/100-150RE07KD0-08 PV7 series pilot-operated imported hydraulic vane pump, made in Germany
| Parameter/Property Category | Direct-Acting (PV7-A) Series | Pilot-Operated (PV7-C/D/N/W) Series | Unit | Remarks |
| Model Range | PV7-1X/06-10RA01MA0-10, PV7-2X/20-25RA01MA0-10 | PV7-1X/14-20RE01MC0-16, PV7-1X/100-118RE07KD0-16 | #VALUE! | 1X/2X=component series; 06/14/20=frame size |
| Displacement per Revolution | 10–25 | 14–150 | cm³/rev | Displacement varies by specific model suffix |
| Max. Continuous Working Pressure | 100 | 160 | bar | PV7-A: ≤100 bar; PV7-C/D/N/W: ≤160 bar |
| Max. Peak Pressure | 120 | 200 | bar | Short-term (≤5s) overload only |
| Speed Range | 600–2800 | 600–3600 | rpm | Higher speed for smaller displacement models |
| Max. Flow Rate (at 1800 rpm) | 36 | 270 | l/min | Calculated at rated displacement |
| Volumetric Efficiency (Rated Condition) | ≥90% | ≥92% | % | At 160 bar, 1800 rpm, ISO VG 46 oil |
| Total Efficiency (Nominal Operation) | ≥80% | ≥82% | % | Includes mechanical & volumetric efficiency |
| Suction Pressure Range | 1 | -0.8 to +1 | bar | Absolute pressure: 0.2–1.1 bar |
| Fluid Compatibility | Mineral oil (HLP), synthetic oil (HETG/HEES) | Mineral oil (HLP), synthetic oil (HETG/HEES) | - | Use FKM seals for synthetic fluids |
| Fluid Viscosity Range | 10–1000 (operation); 2–1500 (start-up) | 10–1000 (operation); 2–1500 (start-up) | mm²/s | Optimal: 16–160 mm²/s |
| Fluid Temperature Range | -20 to +80 | -20 to +80 | °C | Storage: -40 to +90 °C |
| Noise Level (1 m Distance, Rated Operation) | ≤63 | ≤65 | dB(A) | Pilot-operated models have optimized noise reduction |

| PV7-1X/100-118RE07MW6-16WH |
| PV7-1X/16-30RE01MC5-08WG |
| PV7-1X/10-20RE01MC0-10 |
| PV7-1X/63-71RE07MW0-16 |
| PV7-1X/63-94RE07KC0-08 |
| PV7-1X/40-45RE37MC7-16WH |
| PV7-1X/10-14RE01MC0-16-P60Q15 |
| PV7-1X/63-71RE07KW0-16WG |
| PV7-1X/100-118RE07KC5-16 |
| PV7-1X/25-30RE01MC7-16 |
| PV7-1X/63-71RE07MC5-16 |
| PV7-1X/25-30RE01KD0-16 |
| PV7-1X/10-14RE01MC5-16WH |
| PV7-1X/10-20RE01MC0-10-P45 |
| PV7-1X/16-20RE01MW0-16 |
| PV7-1X/16-30RE01MD0-08 |
| PV7-1X/25-45RE01MD0-08 |
| PV7-1X/100-118RE07MC7-16 |
| PV7-1X/10-14RE01MC0-16-P90 |
| PV7-1X/16-20RE01MC7-16WH |
| PV7-1X/40-45RE37MD0-16-C3.1 |
| PV7-1X/40-45RE37MW0-16WG |
| PV7-1X/40-45RE37KD0-16 |
| PV7-1X/40-45RE37MC0-16-P80 |
| PV7-1X/16-30RE01MC5-08 |
| PV7-1X/100-150RE07KD0-08 |
| PV7-1X/40-45RE37MW0-16WH |
| PV7-1X/10-14RE01MD0-16 |
| PV7-1X/100-150RE07MC5-08WG |
| PV7-1X/16-30RE01MC7-08 |
| PV7-1X/63-71RE07MC0-06-A460 |
| PV7-1X/10-14RE01MC0-16 |
| PV7-1X/16-30RE01MN0-08 |
| PV7-1X/25-45RE01KC0-08 |
| PV7-1X/63-71RE07MD0-16-Q85 |
| PV7-1X/100-150RE07MN0-08 |
| PV7-1X/63-94RE07MC3-08 |
| PV7-1X/16-20RE01MW0-16WG |
| PV7-1X/25-30RE01MD0-16 |
| PV7-1X/10-14RE01MW0-16WG |
| PV7-1X/25-30RE01MD5-16WH |
| PV7-1X/10-14RE01MC0-16-P140Q10 |
| PV7-1X/63-71RE07MD5-16 |
| PV7-1X/40-55RE37MC3-08-A449 |
| PV7-1X/40-45RE37MD3-16 |
| PV7-1X/63-71RE07MC0-16 |
| PV7-1X/40-71RE37MC7-08WG |
| PV7-1X/40-45RE37KC3-16 |
| PV7-1X/10-20RE01KC0-10 |
| PV7-1X/25-45RE01MC0-08 |
| PV7-1X/25-30RE01KC0-16 |
| PV7-1X/100-150RE07MC5-08 |
| PV7-1X/40-71RE37KC0-08 |
| PV7-1X/25-30RE01MC6-16 |
| PV7-1X/16-20RE01MC0-16-P55 |
| PV7-1X/25-45RE01MC3-08 |
| PV7-1X/40-45RE37MC6-16 |
| PV7-1X/63-94RE07MW0-08WH |
| PV7-1X/16-20RE01MC0-16-P52 |
| PV7-1X/16-20RE01MD0-16 |
| PV7-1X/25-30RE01MN0-16 |
| PV7-1X/10-14RE01MC6-16 |
| PV7-1X/16-20RE01MC6-16 |
| PV7-1X/100-118RE07MC5-16WH-P125Q116 |
| PV7-1X/16-20RE01MC3-16-C3.1 |
| PV7-1X/100-118RE07MC5-16WH |
| PV7-1X/16-20RE01MD6-16 |
| PV7-1X/25-30RE01MC3-16 |
| PV7-1X/63-94RE07MC0-08-P50Q116 |
| PV7-1X/100-118RE07MC7-16WG |
| PV7-1X/16-20RE01MC0-16-P70Q20 |
| PV7-1X/63-71RE07MD6-16 |
| PV7-1X/100-118RE07MC3-16 |
FAQ:
1. What is the speed range?
The rotational speed range is 900-1800 rpm.
2. What is the maximum displacement?
Maximum displacement ranges from 10 cm³ to 150 cm³ per revolution depending on the model.
3. What are the connection standards?
Connection dimensions are compliant with ISO 6162-1 and ISO 228-1.
4. What is the leakage flow at zero stroke?
At maximum pressure and zero stroke, leakage flow ranges from 1.7 to 8 l/min depending on size.
5. What is the operating temperature range?
The operating temperature range is -20 to +80 °C
|
|
PV7-1X/40-45RE37MC0-16 PV7-1X/16-30RE01MC5-08 PV7-1X/100-150RE07KD0-08 PV7 series pilot-operated imported hydraulic vane pump, made in Germany Images |